Skip Navigation

This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by RIKKERT, M. G. M. O.
Right arrow Articles by HOEFNAGELS, W. H. L.
Right arrow Search for Related Content
PubMed
Right arrow Articles by RIKKERT, M. G. M. O.
Right arrow Articles by HOEFNAGELS, W. H. L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 1998 Oxford University Press

research-article

Individuality and responsiveness of biochemical indices of dehydration in hospitalized elderly patients

MARCEL G. M. OLDE RIKKERT, MARTIN A.VAN'T HOF1, HENK BADDENHUYSEN2 and WILLIBRORD H. L. HOEFNAGELS

Department of Geriatric Medicine, University of Nijmegen PO Box 9101, 6500 HB Nijmegen, The Netherlands
1Medical Informatics, Epidemiology and Statistics, University of Nijmegen PO Box 9101, 6500 HB Nijmegen, The Netherlands
2Laboratory of Clinical Chemistry, University Hospital Nijmegen The Netherlands

Address correspondence to: M. G. M Olde Rikkert Fax: (+31) 24 361 7408

BACKGROUND:: dehydration is common in elderly patients, but difficult to detect, by either an initial assessment of fluid balance or by monitoring fluid balance over time. In clinical chemistry, population-based reference ranges are only of value for monitoring individual patients if within-subject variability in serial test results over time is larger than between-subject variability. This may have important implications in monitoring fluid balance.

AIM:: to assess the within- and between-subject variability of serial laboratory test results in euvolaemia and their responsiveness to dehydration in elderly patients.

METHODS:: over 16 months, 218 patients were admitted to the geriatric department and 53 consented to participate. Fluid balance was assessed twice a week by physical examination, laboratory tests and weighing. Changes in fluid balance were quantified by measuring total body and extracellular water applying deuterium- and bromide-dilution techniques. Within- and between-subject variability in euvolaemia and responsiveness indexes (RI) for dehydration were calculated for haematocrit, serum sodium, urea and creatinine concentrations and for the urea/creatinine ratio.

RESULTS:: during hospitalization 14 patients suffered from dehydration and 27 remained euvolaemic. Data from 12 overhydrated patients were excluded. In a mean study period of 30 days, each patient's fluid balance was assessed 6.3 (1.9) times. This resulted in 1084 laboratory tests and 271 assessments of fluid balance. In all quantities within-subject variability was much smaller than between-subject variability in euvolaemia. Responsiveness of creatinine (mean RI=2.5) was best and similar to the RI of serial weights (mean RI=2.9).

CONCLUSION:: population-based reference ranges are of limited value in monitoring fluid balance. Repeatedly measuring plasma creatinine, combined with physical examination and weighing is the best way to monitor fluid balance in elderly patients.

Keywords: clinical chemistry, dehydration, reference ranges, responsiveness, variability

Received May 14, 1997;
Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Biol Res NursHome page
J. C. Mentes, B. Wakefield, and K. Culp
Use of a urine color chart to monitor hydration status in nursing home residents.
Biol Res Nurs, January 1, 2006; 7(3): 197 - 203.
[Abstract] [PDF]



Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.