Skip Navigation


Age and Ageing Advance Access originally published online on May 18, 2005
Age and Ageing 2005 34(4):382-386; doi:10.1093/ageing/afi108
This Article
Right arrow FREE Full Text (PDF) Freely available
Right arrow All Versions of this Article:
34/4/382    most recent
afi108v1
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Davison, J.
Right arrow Articles by Kenny, R. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Davison, J.
Right arrow Articles by Kenny, R. A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press on behalf of the British Geriatrics Society. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org

Research Paper

24-hour ambulatory electrocardiographic monitoring is unhelpful in the investigation of older persons with recurrent falls

John Davison1, Steven Brady2 and Rose Anne Kenny3

1 Falls and Syncope Service, Royal Victoria Infirmary, Newcastle-upon-Tyne NE1 4LP, UK
2 Department of Cardiology, Royal Victoria Infirmary, Queen Victoria Road, Newcastle-upon-Tyne NE1 4LP, UK
3 3 Cardiovascular Research, Falls and Syncope Service and University of Newcastle-upon-Tyne, Institute for Ageing and Health, Newcastle General Hospital, Newcastle-upon-Tyne NE4 6BE, UK

Address correspondence to J. Davison. Fax: (+44) 191 222 5638. E-mail: John.Davison{at}ncl.ac.uk

Abstract

Background: although frequently used in the assessment of patients with falls, it is unclear whether 24-hour ambulatory electrocardiography contributes to their assessment in older persons.

Objective: to identify electrocardiographic abnormalities in patients with recurrent falls and case controls, and determine whether 24-hour ambulatory electrocardiography identifies causal arrhythmias for falls.

Design: prospective case–control study.

Methods: 24-hour ambulatory electrocardiography recordings were compared for the type and prevalence of arrhythmias and symptom correlation in consecutive older subjects with recurrent falls attending the accident and emergency department and in case controls (no previous falls or syncope). ECG abnormalities were categorised as major (ventricular arrhythmia, pauses, <30b.p.m., Mobitz II, complete heart block) and minor (multiple ectopics, paroxysmal atrial arrhythmia and other bradyarrhythmias).

Results: 128 fallers (76 ±6 years) and 100 case controls (75 ±5 years) were recruited. Co-medication and co-morbidity were similar in both groups. 49% (63) of recordings in fallers and 41% (41) of recordings in controls were abnormal. There was no difference between groups in the prevalence of major or minor abnormalities or of symptoms during recording (breathlessness, fatigue, chest pain and dizziness). Palpitations occurred in 10% of fallers and 13% of controls. One patient fell during monitoring with no associated rhythm abnormality.

Conclusion: multiple abnormalities are present on 24-hour ambulatory electrocardiography in older people whether or not they have experienced falls. 24-hour electrocardiography does not discriminate between fallers and non-fallers and is not helpful in the investigation of recurrent falls.

Keywords: ambulatory electrocardiography, older persons, falls, investigations, elderly

Received December 15, 2004; Revision received April 6, 2005. accepted in revised form April 6, 2005.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.